APC NetShelter Rack PDU Advanced, Switched, 34.6kW, 3PH, 415V, 60A, 560P6, 42 Outlet
search
  • APC NetShelter Rack PDU Advanced, Switched, 34.6kW, 3PH, 415V, 60A, 560P6, 42 Outlet

APC NetShelter Rack PDU Advanced, Switched, 34.6kW, 3PH, 415V, 60A, 560P6, 42 Outlet

109 739 Kč
S DPH

Momentálně nedostupné

Kód: APDU10450SW

  • Barva: Černá
  • Typ: Single-phase
  • Model: Trojfázové
  • Certifikace: CSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1
  • Hmotnost: 12,4 kg
  • Šířka: 56 mm
Všechny parametry
NetShelter Rack PDU Advanced, Switched, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 42 Outlets, IEC309

Popis

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

Parametry

BarvaČerná
TypSingle-phase
ModelTrojfázové
CertifikaceCSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1
Hmotnost12,4 kg
Šířka56 mm
Výška1826 mm
Hloubka75 mm
Provozní rozsah teplot (T-T)-5 - 60 °C
Rozsah teplot při skladování (T-T)-25 - 65 °C
Doporučená provozní relativní vlhkost5 - 95 %
Rozsah relativní vlhkosti při skladování (H-H)5 - 95 %
Frekvence vstupního střídavého napětí50 - 60 Hz
Provozní nadmořská výška0 - 3048 m
Hmotnost včetně balení15,4 kg
Konektor 1IEC 60309
Šířka balení262 mm
Hloubka balení132 mm
Výška balení1980 mm
Hmotnost balení15400 g
Vestavěný displejLCD
Výstupní napětí240 V
Bezpečnostní spínačNe
Typ PDUspínané
Kapacita racku0U
Nominální vstupní napětí200 - 240 V
Maximální proud60 A
PřipevněníVertikální
Počet zásuvek48 AC zásuvky / AC zásuvek
Typy zásuvky pro napájení ze sítěC13 rozdvojovač, C15 rozdvojovač, C19 rozdvojovač, C21 rozdvojovač
Nosnost34600 VA
DisplejLCD
Kruhové zapojeníAno
MontážVertikální
Počet výstupů AC48 AC outlet(s)
Typy výstupů ACC13 coupler,C15 coupler,C19 coupler,C21 coupler
Napájecí zástrčkaIEC 60309
Celková uhlíková stopa (kg of CO2e)5004,04
Neprovozní nadmořská výška0 - 15240 m
Vypínačne
Nominální výstupní napětí240 V
Řetězení zařízení (Daisy Chain)Ano
Maximální vstupní proud na fázi60 A
Maximální celkové napětí tahu za fázi48 A
Maximální celkový proudový odběr na fázi48 A